Contain |
Code |
Percent% |
Cesium tungsten oxide |
52350-17-1 |
~ 6 |
1-Methoxy-2-Propanol |
107-98-2 |
~ 18 |
Nhựa Acrylic |
123-86-4 |
10 ~ 23 |
Butyl Acetate |
2440-22-4 |
10 ~ 23 |
2-(2H-Benzotriazol-2-yl)-p-cresol |
~ 7 |
|
Ethylene Glycol Monobutyl
Ether Acetate |
112-07-2 |
~ 38 |
Technical Data Sheet
1. Heat insulation
IRUV CUT COAT test report-001 NSG Techno-Research Corporation June 2003.
“Optical properties and thermal characterization of coated glass”
Visible light transmission | Transmittance sunshine | Solar reflectance | Solar radiation Absorption rate | UV transmittance |
68.0% | 39.9% | 5.0% | 55.1% | 0.33% |
Solar heat gain rate | Shading coefficient | ||
Summer | Winter | Summer | Winter |
0.59 | 0.56 | 0.67 | 0.63 |
2. Heat resistant cracking
IRUV CUT COAT test report-001 NSG Techno-Research Corporation June 2003.
“Thermal cracking test”
Direction | East | Southeast | South | |||
Thermal cracking judgment | OK | OK | OK | |||
Season | Summer | Winter | Summer | Winter | Summer | Winter |
Temperature of central portion (0C) | 44 | 4 | 46 | 24 | 36 | 26 |
Sash temperature (0C) | 25 | -10 | 27 | 7 | 27 | 7 |
Thermal stress occurs (kg/cm2) | 125 | 89 | 125 | 125 | 54 | 125 |
Allowable thermal stress (kg/cm2) | 180 | 180 | 180 | 180 | 180 | 180 |
Heat stress difference (kg/cm2) | 44 | 91 | 55 | 55 | 126 | 55 |
Direction | Southwest | West | ||
Thermal cracking judgment | OK | OK | ||
Season | Summer | Winter | Summer | Winter |
Temperature of central portion (0C) | 47 | 26 | 47 | 18 |
Sash temperature (0C) | 28 | 7 | 28 | 4 |
Thermal stress occurs (kg/cm2) | 125 | 125 | 125 | 90 |
Allowable thermal stress (kg/cm2) | 180 | 180 | 180 | 180 |
Heat stress difference (kg/cm2) | 55 | 55 | 55 | 90 |
3. Adhension
KOKANKYO Engineering Co., Ltd. In April 2006
“Weather resistant coating agent test report”
Item |
Method |
Result |
Standard |
Boiling water resistance |
1 hour boiling water immersion |
Ο |
|
Gasoline resistance |
Gasoline rubbing 200 |
Ο |
|
Solvent resistance |
Xylem rubbing 200 |
Ο |
|
0.1 sodium hydroxide |
Ο |
||
Chemical resistance |
5% sodium hydroxide |
X |
|
10% nitric acid |
Ο |
||
10% sulfuric acid |
Ο |
||
Scratch hardness |
Pencil method |
9H |
JIS K5400 |
Adhension |
Cross-cut adhension test |
100/100 |
JIS K5400 |
4. Durability
KOKANKYO Engineering Co., Ltd. in April 2006
“Weather resistant coating agent test report”
Tested by a xenon lamp weather over (equivalent to approximately 10 years) 2580 hours
Test Result |
The change is not accepted by a color, a film |
March, 2008 DAINICHISEIKA Color & Chemicals Mfg, Co., Ltd.
Super UV irradiation testing and pencil hardness test
Yellowing, cloudiness and evaluation
Blank |
100 hour |
200 hour |
|
Sample 1 |
Ο |
Ο |
Ο |
Sample 2 |
Ο |
Ο |
Ο |
Pencil hardness test (JIS K5400)
Blank |
100 hour |
200 hour |
|
Sample 1 |
4H |
4H |
4H |
Sample 2 |
4H |
4H |
4H |
5. Safety
• Volatile Organic Compounds (VOC)
Japan Food Research Laboratories Co., Ltd. In August 2006
“Formaldehyde test”
Analysis of test items |
Test result |
Detection limit |
Method |
|
Formaldehyde emission |
0.12mg/L |
Note (*) |
Absorption spectrophotometer |
(*) Note 1. JIS K5601-4-1: 2003
6. Combustion test
Japan Railway Rolling Stock & Machinery Association in October 2004
Test number 16-526K
During combustion of alcohol |
After combustion of alcohol |
||
Ignition |
No |
After flame |
- |
Wear flame |
No |
Residual dust |
- |
Smoke |
No |
Carbonization |
60mm discoloration |
Force of flame |
- |
Deformation |
No |
Remarks |
|||
Remarks |
|||
Assessment |
Non-combustible |
Tested with No.151 Ordinance of the “Ministry of Land, Infrastructure, Transport and Tourism”
7. Save Electricity Cost
KOKANKYO Engineering Co., Ltd. in October 2005
Sheet electricity costs for the first year of use conditioner (15 yen / kWh)
Exchange Rate 11/2013: 1 Yen = 200 VNĐ
Name |
Normal Glass |
Glass with the Insulating IRUV Cut Coat H-SC |
Conditioner |
639,278 Yen (127,855,600 VND) |
544,521 Yen (108,904,200 VNĐ) |
Deviation’s electricity cost |
- 94,756 Yen - (18,951,200 VNĐ) |
|
Down 16% |